Abstract
Background:
Glucose tolerance can be assessed noninvasively using 13C-labeled glucose added to a standard oral glucose load, by measuring isotope-enriched CO2 in exhaled air. In addition to the clear advantage of the noninvasive measurements, this approach may be of value in overcoming the high variability in blood glucose determination.
Methods:
We compared within-individual variability of breath CO2 isotope enrichment with that for blood glucose in a 75-g oral glucose tolerance test (OGTT) by adding 150 mg of
Results:
Breath test-derived measures exhibited lower within-subject variability than the 2-h OGTT glucose. The coefficient of variation for ∂‰180 was 7.4 ± 3.9% (mean ± SD), for AUC180 was 9.4 ± 6.3%, and for 2-h OGTT blood glucose was 13 ± 7.1% (
Conclusions:
Breath test-derived measurements of glucose handling had lower within-subject variability versus the standard 2-h blood glucose reading used in clinical practice. These findings support further development of this noninvasive method for evaluating glucose tolerance.