Abstract
Keywords
INTRODUCTION
Use of 15O-labeled molecular oxygen (15O2) is an ideal molecule for tracing the kinetics of oxygen

Tracer model commonly employed for describing radioactivity kinetics after 15O2–hemoglobin (15O2–Hb) injection. The model consists of a vascular compartment, a non-metabolized oxygen compartment, and a metabolized water compartment. Negligible amount of back diffusion in the form of 15O-labeled oxygen (15O2) is attributed to the short life time of molecular oxygen in the cerebral tissue. No accumulation or retaining system exist for 15O2 oxygen, neither for 15O-labeled water (H25O). BBB, blood–brain barrier.
The clearance of 15O-radioactivity after the intracarotid bolus injection of 15O-labeled oxygen (15O2) in the form of oxyhemoglobin has been first measured using a single gamma photon detector in humans. Slopes were claimed to be consistent between 15O2–oxyhemoglobin (15O2–Hb) and H25O,8,9 but a significant level of background due to the limited collimation of the detector was a limitation. Thus, another experiment was carried out recently by Seki
In the present study, we intended to reevaluate the adequacy of the compartmental model commonly employed for 15O2-inhalation PET studies using a bigger animal. Clearance of the radioactivity concentration in local brain regions were quantitatively assessed on the nonhuman primate of Macaca fascicularis after the ICA injection of 15O2–Hb and H25O, from sequentially acquired tomographic images using an advanced PET scanner. We then evaluated whether or not we are able to identify the significant difference in the clearance slopes between the 15O2–Hb and H25O samples.
MATERIALS AND METHODS
Subjects
Two monkeys (
Animal Preparation
Anesthesia was induced with ketamine (10 mg/kg, intramuscularly) and maintained by intravenous propofol (4mg/kg per hour) and vecuronium (0.05 mg/kg per hour) during the experiment. Animals were intubated and their respiration was controlled by an anesthetic ventilator (Cato; Drager, Lubeck, Germany) providing a gas mixture of 24% O2 and 76% N26,7,11. A catheter was inserted into the ICA for intracarotid bolus injection of 15O2–Hb, H25O, and C15O–hemoglobin (C15O–Hb). A catheter was also inserted into the femoral artery for monitoring the blood pressure, heart rate, O2 content, and the partial pressures of carbon dioxide level in arterial blood. Additional catheter was placed to the anterior tibial vein, and was utilized for infusing the anesthetic agents.
Preparation of 15O2–Hemoglobin, C15O–Hemoglobin, and H25O–Saline
15O-radioactivity was produced by the 14N(d,n)15O nuclear reaction with a 0.5% O2/N2 gas target using a CYPRYS-HM18 cyclotron (Sumitomo Heavy Industry, Tokyo, Japan). The bombarded target gas including the produced 15O2 was transported to an in-house synthesizer system to achieve high radiochemical purity for each 15O2 and C15O gases. The 15O2–Hb and C15O– Hb were prepared using the labeling system developed by Magata

Schematic diagram of a system to generate the blood samples containing 15O2–hemoglobin (15O2–Hb) and C15O– hemoglobin (C15O–Hb). The system is the same as the one described in Magata
The 15O2 gas was also transferred to H25O using a radioactive water generator 14 to produce the injectable saline containing H25O. The H25O–saline was diluted by the arterial blood of more than eight times volume, and had radioactivity of ˜20 MBq in 0.4mL at the time of bolus injection into the ICA.
Positron Emission Tomography Experiments
The PET scanner was ECAT HR, Siemens-CTI (Knoxville, TN, USA) containing BGO scintillator blocks, which can acquire the data either in two-dimensional or in three-dimensional modes. The scanner provides tomographic images for 47 slices for an imaging field of view of 55 cm in diameter and 15 cm in axial length. The intrinsic spatial resolution was 5.8 mm in full width at half maximum at the center of the field of view. Observed spatial resolution after applying the three-dimensional Gaussian post filter, the observed spatial resolution was ˜10 mm.
At least 1hour after the end of the preparation for catheter, we confirmed that the heart rate, the arterial blood pressure, and the arterial partial pressures of carbon dioxide and oxygen can be maintained constant, a series of PET scans were initiated. A 900-second transmission scan was first carried out using a rotating 68Ge-68Ga rod source for the attenuation correction. Each of 15O2–Hb (˜17 MBq), H25O–saline (20 MBq), and C15O–Hb (17 MBq) samples of 0.4 mL were injected in 3 to 4 seconds into either the right or the left ICA. Three sets of list mode acquisition were carried out in two-dimensional mode for 5.5 minutes, for each injection. The order was the same in all three experiments, because this is the easiest protocol in our radio synthesizing system.
Data Analysis
The list mode data were sorted to produce dynamic sinogram for each scan, with frame durations of 30 times 1 second, 15 times 2seconds, 12 times 5 seconds, and 18 times 10seconds, in total 5minutes. Images were then reconstructed using a filtered back projection technique, including corrections for dead time, the radioactive decay, detectors normalization, attenuation, and scatter, using the vendor software programs. Dynamic PET images following the intracarotid injection of H25O were added over the initial 50seconds after the peak of the head curve. Five regions of interest were defined on this image for each experiment (see Figure 3), in the middle cerebral artery territory of the injected hemisphere on different slice levels, providing five sets of clearance curves for each injection. Angiography was carried out in order to confirm the location for the coronary arterial injection. It was also monitored that 0.4mL sample does not interfere the natural cerebral circulation. Each clearance curve after the 15O2–Hb and H25O–saline injection was fitted to a single exponential function during the first 5 to 40seconds (early), and 80 to 240 seconds (late) periods after the peak. Mean and s.d. were calculated for slope values for each of the early and late phases, and also for both 15O2–Hb and H25O–saline for each experiment. Significant difference in the slope parameters was identified between 15O2–Hb and H25O–saline, using a Student's

(
RESULTS
Positron emission tomography scans were successfully carried out on all animals for all injections, with the variation of partial pressures of carbon dioxide < 1mmHg, the systolic/diastolic blood pressure < 4mmHg, the heart rate < 5% throughout the study at each experiment. Typical coincidence counting rate of the whole PET gantry was ˜35, 60, and 30kcps at peak, corresponding to the 15O2–Hb, H25O–saline, and C15O–Hb injections, respectively. The dead time counting loss was < 5% at peak in all scans.
Figure 4 shows a typical example of the clearance curves obtained following the 15O2–Hb, H25O–saline, and C15O–Hb sample injections into one of the experiments in middle cerebral artery territory of the central slice. The clearance is rapid after the C15O–Hb sample injection, while they consisted of slower slopes with 15O2–Hb and H25O–saline injections. It can be seen that the clearance slopes after 5 seconds of the peak consisted of the early (faster) and delayed (slower) components in all experiments with the 15O2–Hb and the H25O–saline injections. A sharp peak was visible after the 15O2–Hb blood sample injection at the beginning, but this was not seen after H25O sample injection. It can also be seen that the clearance slopes were visually identical between the 15O2–Hb and the H25O–saline injections in both early (5 to 40 seconds) and late (70 to 240 seconds) phases. Results from the fitting of the clearance slopes for both the early (faster) and late (slower) slopes to the single exponential function are summarized in Table 1. Interslice variations of the slope values were 10% to 20% in each experiment, for both the early (fast) and the late (slower) slopes in the 15O2–Hb and the H25O–saline injections. Within these variations, no significant difference was detected between 15O2–Hb and H25O–saline injections in each of the three experiments for both the early (fast) and the late (slower) slopes. The residues of the fitting showed no significant correlation in relation to the time on the logarithmic domain, in the early and late phase slopes, both for the 15O2–Hb and H25O–saline injections in each of the three experiments.

Typical results from the clearance measurement, with results of fitting by single exponential function for the early (5 to 40 seconds) and late (80 to 240 seconds) periods, indicated with blue and red lines, respectively. Clearance curves are similar between the two curves obtained from the internal carotid artery injection of 15O2-hemoglobin (15O2–Hb) and 15O-labeled water (H25O). The clearance was faster for C15O–hemoglobin (C15O–Hb) injection. PET, positron emission tomography.
List of hemodynamic parameters and summary results of clearance slopes fitted the single exponential function to the first 5 to 40 seconds (early) and 80 to 240 seconds (late) phases after the peak of the clearance curves
HB, hemoglobin; H25O, 15O-labeled water; 15O2–Hb, 15O2–hemoglobin;
Figure 5 shows the Bland–Altman's plots demonstrating the difference in the clearance slope values being not significantly different between the 15O2–Hb and H25O–saline injection both in the early (faster) and late (slower) phases, at each of the three experiments. One s.d. values of the differences were 0.078 minutes and 0.041 minutes, and the averaged values between the 15O2–Hb and H25O–saline injections 0.442 minutes and 0.258 minutes corresponding to the early (faster) and late (slower) slopes, respectively, resulting in the ratio of these values being 17.6% and 15.9% for the entire analysis.

Results from the Bland–Altman plot analysis obtained from the single exponential fitting analysis for each of the three experiments, and for all pooled data (All). The agreement of the two assessments showed uncertainty of ˜20% (1 s.d. of 0.078 and 0.041 at averaged slope value of ˜0.4 and 0.2 corresponding to the faster and slower components, respectively) for each of the two components. 15O2–Hb, 15O2– hemoglobin; H25O, 15O-labeled water.
DISCUSSION
The clearance slopes of 15O-radioactivity following the slow bolus injection of 15O2–Hb, H25O–saline and C15O–Hb into the ICA were determined for local cerebral regions using sequential PET imaging in three independent experiments on two monkeys (
Accuracy of the assessment is well supported in two-dimensional PET, by involving corrections for detector inhomogeneity, random coincidence, dead time, attenuation and scatter, and the well-established reconstruction procedures. Contamination of signals and hence, random coincidence events can be accurately corrected, and were only small in this study. The dead time count loss was only less than 5% at the peak of total counting rate of ˜60kcps over the whole field of view. Use of an artificial lung 12 should have contributed to minimize the risk for the possible damage of the red cells and hemoglobin during the labeling procedures. The injected sample volumes of 0.4mL into an over a 3 to 4seconds period (namely 0.1 mL/second or 6mL/minute) was smaller than the natural cerebral perfusion of ˜20 mL/minute, as estimated by assuming the averaged regional perfusion of 0.3 mL/minute per gram, and the whole brain weight of 60g. Injection of the samples applied in this study thus unlikely causes disturbance in the cerebral circulation. It should also be noted that the contribution of recirculation of injected radioactivity can be considered only small, because only a small fraction of injected radioactivity can return the cerebral tissues. As the decrease of the brain radioactivity was only 2 to 3 times even at the end of the PET imaging, amount of the recirculating radioactivity should cause negligible effects. Despite the small number of the experiments, the results from this study suggest that the presence of significant difference in the clearance slopes between 15O2–Hb and H25O injections would be unlikely. Most of the previous approaches5–7,15–17 that quantitatively assessed CMRO2 and CBF in various clinical settings, which stand for these assumptions, are thus considered to be adequate.
It has been believed that oxygen is excessively delivered into intact brain as compared with its utilization, resulting in significant amount of oxygen tension in the brain tissue
18
. This suggests that the back diffusion of radioactivity could exist in the form of 15O2 from the tissue to the blood. However, the effective contribution of the back diffusion was not visible in the clearance slopes, namely no significant difference was seen in the slopes between the 15O2–Hb and H25O–saline injection in the present study. This is attributed to the short life time of oxygen molecule in the brain tissue associated with the high oxidative metabolism in the cerebral tissue. Our results are, however, controversial to those by Seki
There are limitations in this study: (a) Only three independent experiments were carried out on two monkeys. Limited sample size is clearly the weakness of this study. This was simply due to the difficulty of having more animals for this experiment. Given the reproducibility being 17.6% and 15.9% among PET slices corresponding to the faster and slower clearance slopes, however, additional experiments on different animals likely cannot detect significant differences between the 15O2–Hb and H25O–saline injections, even if it exists. (b) Positron emission tomography scans were carried out only at the baseline condition during the anesthesia, but not during hyperemia or other stressed conditions. This was due to the need for minimizing the possible damage to the animals, as they were scheduled to participate in another study of evaluating the revascularization therapeutic trials after embolic stroke. Repeating the same set of experiments in the stressed conditions is more challenging to maintain the arterial partial pressure of carbon dioxide, the heart rate, and the blood pressure. We were also concerned that no reason is clearly shown why the clearance slope could be altered after the physiological stimulation. It would however be of an interest to confirm the identical slope values also after the physiological stress is involved, in the future. (c) Due to the limited spatial resolution of the PET device employed in this study (˜10mm full width at half maximum), there must be significant contribution of heterogeneity of CBF and CMRO2 within a selected ROI. This includes not only the gray matter and white matter heterogeneity, which could be observed as faster and slower clearance slopes in this study, but also in homogeneous distribution in a small local area within the selected ROI. (d) The clearance slopes ranging from 0.37 to 0.45 minutes for the faster component was smaller than the clearance slope-based CBF values reported previously with PET involving the partial volume correction on monkeys
19
. This could be attributed to different anesthesia protocols. In this experiment, anesthesia was maintained under the continuous intravenous infusion of propofol, while in the earlier study, the anesthesia was maintained by repetitive intramuscular injections of a mixture of xylazin and ketamine. Kaisti
In conclusion, dynamic PET imaging was performed to investigate differences in the clearance rates of cerebral 15O-radio-activity after bolus injections of 15O2–Hb and H25O into the ICA. Analysis of the bi-exponential time–activity curves suggested that a significant difference between the rates is unlikely for both the early and late stage data. Even though the number of experiments should be increased to improve the statistics, the results imply that the mathematical model presented in Figure 1 is adequate for quantitative assessment of CMRO2 and may encourage further development of PET protocols to improve performance and logistics.
