Abstract
Keywords
Introduction
The electrosurgical unit was invented in 1927, 1 but over the last 2 decades, electrosurgery has become more popular worldwide. 2 The advantages of an electrosurgical unit are high cutting speed, positive hemostatic effects, ease of operation, and safety. Consequently, the percentage of surgeons who perform electrosurgery has considerably increased.2–5
The electrosurgical unit relies on a current passing through tissue to produce heat to complete separation and coagulation. 3 Previous studies have simulated the temperature field during tissue cutting with an electrosurgical unit by ANSYS. 4 These studies showed that the tip temperature of the knife was 214.4°C at 20 W of power, 301.7°C at 60 W, 436.6°C at 70 W, and higher than 500°C at 80 W.
During electrosurgery, a high temperature at the tip of the knife pyrolyzes the tissue and produces large volumes of high-temperature surgical smoke. Many studies have analyzed surgical smoke.6–10 There are several harmful components in surgical smoke (especially carbon monoxide [CO]) that endanger the health of all staff in the operating room. At the same time, the work load of surgeons is higher than ever. Surgeons may work an entire day in the operating room and are forced to be in contact with surgical smoke every day during the working week. 10 However, few reports have studied the distribution of surgical smoke in the operating room during electrosurgery to help surgeons avoid concentrated zones of surgical smoke. 11 There have been even fewer studies on the health effects of exposure (continuous working or working with 1-day intervals, i.e., gd/gd-alt) to surgical smoke for surgeons. 11
This study aimed to examine the distribution of surgical smoke in operating rooms. We also investigated the effect of exposure (gd/gd-alt) to surgical smoke in high-/low-concentration zones for surgeons using a statistical method based on rabbit experiments. We established a mathematical model to clarify the concentration regions of surgical smoke and to study the effect of an evacuator. These results will help surgeons protect themselves by standing in the correct location in an operating room and by making reasonable operating schedules.
Methods
Measurement of surgical smoke in an actual operating room
We measured the distribution of surgical smoke to examine the effect of surgical smoke on surgeons who are continuously working in the operating room. CO content at certain positions in the operating room was measured with a portable CO detector (SKY8000 CO detector; Shenzhen Unitec Technology Co., Ltd., Shenzen, China) during electrosurgery. The measurement positions were at the four corners of the operating table at a height of 1 m from the floor (Figure 1).

Measuring points in the operating room
Rabbit experiments
Using measured data of surgical smoke during surgery, the effect of surgical smoke on blood indices of surgeons continuously working in the operating room was studied by experiments on rabbits. Rabbits were exposed to gas that contained CO, carbon dioxide (CO2), oxygen (O2), and nitrogen (N2) for certain time intervals. This procedure simulated surgical smoke exposure during electrosurgery.
The animal use protocol was reviewed and approved by the Animal Ethical and Welfare Committee (AEWC) of Wuhan University of Science and Technology, China.
Experimental conditions
The simulation cabin was a hexahedral airtight Perspex cabin with a volume of 2 m3. The input gas flow rate was 18 m3/h, the temperature and humidity were 25 ± 2°C and 70% ± 10%, respectively, and five rabbits were kept in each cabin.
CO and CO2 were distributed and imported into the simulation cabin through intake using a precise gas distributing facility. The chemical analysis of gas in the cabin was tested with a gas chromatograph (Agilent 7890B; Agilent Technologies Inc., Wilmington, DE, USA).
Experimental methods
The animals used in these experiments were male Japanese rabbits, weighing 2 to 3 kg. Eighty rabbits were randomly divided into the following five groups: normal control (NC), daily low-level surgical smoke exposure (L-gd), daily high-level surgical smoke exposure (H-gd), low-level surgical smoke exposure with a 1-day interval (L-gd-alt), and high-level surgical smoke exposure with a 1-day interval (H-gd-alt). For the NC group, the rabbits were fed in the simulation cabin with imported fresh air for 5 days. For the L-gd and H-gd groups, the rabbits were fed in separate simulation cabins with imported low-content or high-content surgical smoke for 8 hours per day for 5 days. For the L-gd-alt and H-gd-alt groups, the rabbits were fed in separate stimulation cabins with imported low-content or high-content surgical smoke for 8 hours per day with a 1-day interval for 5 days.
Measurement of blood indices
Ear arterial blood (0.8 mL) was collected with a sterile syringe from each rabbit before and after surgical smoke exposure. Each blood sample was injected into a sample tube containing heparin. Each sample was then shaken and immediately placed on ice. The blood gas indices of each sample were measured with an iStat-300 blood gas detector (iStat-300G; Abbott, Chicago, IL, USA) 30 minutes after sampling, and carboxyhemoglobin (HbCO) levels were measured with a spectrophotometer (722S spectrophotometer; Shanghai Instrument Electric Analytical Instrument Co., Ltd. Shanghai, China) after sampling.
Statistical methods
Measured indices of each group were compared using the program SPSS for Windows, Version 13.0 (SPSS Inc., Chicago, IL, USA). The measured results for pH, O2 saturation, O2 content, and HbCO levels are shown as the mean ± standard deviation. Statistical calculations were performed using the independent sample t-test and two-way analysis of variance. Statistical results with a
Mathematical simulation of surgical smoke distribution in the operating room
On the basis of the rabbit experiment data, which clarified the effect of surgical smoke on blood indices of surgeons working continuously in the operating room, a mathematical model was constructed using the FLUENT 15.0 program (Ansys Inc., Canonsburg, PA, USA).. This model was established to determine the distribution route of surgical smoke during surgery for better protection of surgeons. In addition, a geometric model of an operating room was created. The conditions of the simulation model were estimated on the basis of the actual flow rate of surgical smoke from an electro-knife tip with a constant temperature and cutting speed. The parameters of the model are shown in Table 1.
Parameters for a simulation model for surgical smoke distribution in an operating room
L: length; H: height; W: width; CO: carbon monoxide; CO2: carbon dioxide; O2: oxygen; N2: nitrogen
The governing equations of this model included the continuity equation, Navier–Stokes equations, the k-ε turbulence model, and the dynamic model of particles. The flow and mixture of surgical smoke were estimated using the multiphase mixture model in FLUENT 15.0.
The boundary conditions of the mathematical model were as follows. (1) The inlet of laminar air flow was set as the velocity inlet. (2) The outlet of laminar air flow was set as the pressure outlet, with a pressure of 0 pa. (3) The incision at the center of the operating table surface was set as the inlet of surgical smoke. (4) The velocity distribution at the four walls of the operating room was estimated with wall function. (5) Heat transfer of the walls of the operating room was set as the third boundary condition. (6) The ceiling and floor of the operating room were adiabatic.
The operating room was divided into 3 × 105 grids. The simulation was performed using the finite volume method, where the model algorithm was the Pressure Implicit Split Operator method and the discrete scheme was the second order upwind difference scheme.
Results
Measurement data in an actual operating room
During laparotomy with an electro-knife (power 40 W), the CO content of four points in an actual operating room was measured. Simulation results of surgical smoke in the operating room showed that CO content at both sides at the edge of the middle part of the operating table (0.014%–0.015%) was much higher than that at the head or foot part of the operating table (0.0049%–0.0050%) (Table 2). At each location, actual measurements were recorded four times and the mean of these measurements was reported (Table 2). We found that the center region of the operating table had the highest content of surgical smoke. This region was called the high-content zone (HCZ) for surgical smoke. The mean gas contents in this region were 1.5 × 10−2% for CO, 3.0 × 10−2% for CO2, and 20% for O2. The regions near the operation table’s foot and head end had the second highest content of surgical smoke. These regions were called the low-content zone (LCZ) for surgical smoke. The mean gas contents in this regions were 5 × 10−3% for CO, 1.0 × 10−2% for CO2, and 20% for O2. The differences between simulation data of the mathematical model and actual measurement results ranged between 1% and 9%. Therefore, the simulation model was verified and could be used to analyze the distribution of surgical smoke in an operating room.
Measurement of surgical smoke at four points in the operating room
CO: carbon monoxide; CO2: carbon dioxide; O2: oxygen
Rabbit experiments
We examined two levels of CO and CO2 content, and the experimental conditions for each group are shown in Table 3.
Experimental conditions for each rabbit group
CO: carbon monoxide; CO2: carbon dioxide; O2: oxygen; NC: normal control; L-gd: daily low-level surgical smoke exposure H-gd: daily high-level surgical smoke exposure; L-gd-alt: low-level surgical smoke exposure with a 1-day interval; H-gd-alt: high-level surgical smoke exposure with a 1-day interval. n = 4 rabbits in each group
As shown in Table 4, there were no significant differences in all measured blood indices before exposure to surgical smoke between the exposure groups (L-gd/H-gd/L-gd-alt/H-gd-alt) and the NC group. However, after exposure to surgical smoke, there were some significant differences between the groups. The L-gd group had significantly higher HbCO levels after exposure to surgical smoke compared with the NC group (
Blood indices after surgical smoke exposure
**
Two-way ANOVA showed that exposure to high or low surgical smoke content in the operating room significantly affected all blood indices (all
Two-way analysis of variance results of experimental data
**
Simulation results of the mathematical model
As shown in Figure 2, many observations were observed from the mathematical model. First, surgical smoke was driven upward because of natural convection and a large volume of gas from a high-temperature incision. Additionally, laminar air flow from the ceiling pushed the upwelling surgical smoke downward. Furthermore, the surgical smoke spread around the operating table during electrosurgery. In the center of the operating room, the highest concentration of surgical smoke was directly above the incision, 1.5 m from the floor, and 0.5 m from the surface of the operating table. Therefore, the zone within < 0.5 m in height and 0.5 m around the incision in a horizontal direction was deemed the zone with a high content of surgical smoke. In this area, the CO content ranged from 0.5 to 2.0 × 10−2% (HCZ, A zone in Figure 2). Surgical smoke spread out around the operating table. Most smoke flowed to the two walls with laminar air outlets, while a small amount of surgical smoke flowed to the two other walls without outlets. This subset of smoke was recirculated and remained in the operating room. The zone < 2.1 m from the wall without an air outlet had a low level of surgical smoke, with a CO content that ranged from 1.5 to 5 × 10−3% (LCZ, B zone in Figure 2). The region outside the HCZ and LCZ was minimally contaminated by surgical smoke, with a CO content < 1 × 10−4% due to laminar air flow in the operating room. This area was named the non-contaminated zone (NCZ).

Distribution of surgical smoke in the operating room (laparotomy, electro-knife power: 40 W)
With an evacuator, the plume height of surgical smoke was decreased and the range of the HCZ was reduced (Figure 3). However, the range of the LCZ was enlarged. This occurred because the plume of surgical smoke was driven to one side of the operation table by the evacuator, and was easily blown over by down flow from the roof in the operating room. The evacuator had no effect on the NCZ.

Distribution of surgical smoke in the operating room with an evacuator
Discussion
During laparotomy with a 40 W power electro-knife, the CO content in the HCZ of the operating room ranged from 50 to 200 ppm. This content is much greater than the 9 ppm upper limit for an 8-hour exposure set by the Unites States Environmental Protection Agency (EPA). 12 The CO content in the LCZ ranged from 15 to 50 ppm, which was also greater than the EPA upper limit. The CO content in the NCZ was less than 1 ppm, which was within the EPA upper limit. Therefore, surgeons should avoid the HCZ and the LCZ in the operating room during laparotomy with an electro-knife. Standing inside the NCZ is recommended for surgeons performing electrosurgery.
If surgeons were to continuously stand in the HCZ throughout their work days, their pH, HbCO levels, O2 saturation, and O2 content would likely be abnormal. In our rabbit experiments, the mean HbCO level in rabbits that remained in the HCZ for 5 days was 20.7 times higher than that in rabbits without exposure to surgical smoke. If surgeons were to stand in the HCZ with a 1-day interval between work days, their pH, HbCO levels, and O2 content indices would still likely be abnormal. The average HbCO level of rabbits that were exposed to high levels of surgical smoke daily or with an interval day was greater than 8.8% in our study. A previous study showed that rats that were exposed to a side stream of cigarette smoke had a mean HbCO level of 8.5%. 13
If surgeons were to continuously stand in the LCZ throughout their work days, their HbCO levels would likely be abnormal. In our study, the mean HbCO levels of rabbits that remained in the LCZ for 5 days was 9.8 times higher than that in rabbits without exposure to surgical smoke. If surgeons were to stand in the LCZ with a 1-day interval between work days, their HbCO levels would still likely be abnormal. The average HbCO level in rabbits that were exposed to surgical smoke equivalent to the LCZ zone daily or daily with an alternate interval was greater than 2.57%. A previous study showed that the mean HbCO level in individuals who smoke cigarettes in the long term was 2.93%. 14
Our mathematical model showed that, when exposed to surgical smoke with a 1-day interval, HbCO levels were decreased by 24% when standing in the HCZ and HbCO levels were decreased by 56% when standing in the LCZ compared with continuous exposure day after day. Therefore, surgeons who maintain a 1-day interval between electrosurgeries can protect against harmful effects of surgical smoke. If CO levels in the HCZ and LCZ in an operating room are higher than the upper limit for 8-hour exposure as set by the US EPA, 12 exposure to CO may result in tissue hypoxia, which is harmful to health.15–18
The World Health Organization recommends an HbCO level of 2% for indoor air quality. HbCO levels > 2% can cause ST-segment changes and decreased time to angina.19–21 In our study, all five surgical smoke exposure groups had HbCO levels higher than 2.5%. This finding indicates that staying in the HCZ and LCZ in the operating room is harmful to surgeons. The commonly accepted blood HbCO thresholds for the diagnosis of CO poisoning is 10% in smokers and 5% in non-smokers. 22 Therefore, individuals with HbCO levels > 10% may have headaches and feel weak. The mean HbCO level for the H-gd group was 11.61%. This finding suggests that surgeons who work all day every weekday in the HCZ of an operating room should rest immediately to allow their HbCO levels to recover.
Our study showed that working at a region with a high content of surgical smoke in the operating room could be more harmful to surgeons than working continuously in the operating room for several days. Surgeons should stand in the correct location in the operating room during electrosurgery and manage their operating schedule to avoid health hazards from surgical smoke exposure.
The present study showed that an evacuator could reduce the range of the HCZ for surgical smoke using mathematical model simulation. However, an evacuator could also enlarge the LCZ for surgical smoke in the operating room during surgery because it causes blowing over of the plume of surgical smoke. Therefore, even with an evacuator, blood indices of surgeons who continuously work in the operating room for 1 week could be affected by surgical smoke.
Conclusions
Our mathematical model shows that, during electrosurgery, there is a highly contaminated zone within 0.5 m around the heated tip of an electro-knife and a low contaminated zone within 2.1 m from the two walls without a laminar air outlet. In these zones, CO levels are above the United States EPA upper limit for an 8-hour exposure. Our rabbit experiments show that exposure to surgical smoke results in high HbCO levels. Exposure to the highly contaminated zone of surgical smoke for 5 continuous days significantly affects pH, HbCO levels, O2 saturation, and O2 content. Exposure to surgical smoke also leads to a mean HbCO level > 2%, which is the World Health Organization guideline for indoor air quality. Continuous exposure to a high level of surgical smoke leads to a mean HbCO level above the threshold for diagnosis of CO poisoning. Surgeons should stand in the correct location in the operating room during electrosurgery and manage their operating schedule to avoid health hazards from surgical smoke exposure.