Abstract
Keywords
Introduction
Measurement of nuchal translucency (NT) is an important marker in antenatal screening for Down’s syndrome, trisomy 18 and trisomy 13. Over time, the precision of measuring NT has improved leading to a reduction in the standard deviation. For example, at 12 completed weeks’ gestation, the log10 NT MoM (multiple of the median) standard deviation was 0.1329, 0.1105 and 0.0855 in 2003, 1 20102 and 2018,3,4 respectively, as reported from the Wolfson Institute Screening Service. The distribution of NT is positively skewed; after log transformation, the distribution is reasonably Gaussian, but there is still a degree of positive skew. 5 To deal with screening markers deviating from Gaussian distributions in the tails of the distributions, it is standard practice to specify truncation limits in which values above or below these limits are assigned values at the truncation limits.6,7
As NT measurement has become more precise, there is a case for lowering the upper truncation limit from the 2.5 MoM value 2 set in 2010 to take account of the positively skewed distribution of log-transformed NT MoM values. We here examined data from the Wolfson Institute of Preventive Medicine Antenatal Screening Programme to determine whether there was a need to revise the NT upper truncation limit.
Methods
Data from a 2018 audit of antenatal screening were used based on measurements from 22,362 unaffected singleton pregnancies and 69 Down’s syndrome pregnancies. 8 A probability plot was generated for the NT MoM values and inspected to determine if the upper truncation limits should be lowered from the currently specified value of 2.50 MoM. 2 A term Down’s syndrome risk estimate was calculated from the NT measurements for each of the 22,362 unaffected singleton pregnancies and 69 affected singleton pregnancies. The risk estimates were calculated by previously described standard methods 9 from the overlapping log10 NT MoM Gaussian distributions of affected and unaffected pregnancies, using published sets of NT distribution parameters2,4,10 (see Appendix 1), the observed overall Down’s syndrome prevalence in the sample population and the currently specified NT upper truncation limits of 2.50 MoM and 2.0 MoM.
To assess the accuracy of risk estimation using the two NT upper truncation limits, validation plots11,12 were created in which the risk estimates were ranked and put into seven categories with approximately equal numbers of affected pregnancies in each category. Within each category, the median risk and the observed prevalence of Down’s syndrome were calculated. The accuracy of risk estimation is displayed by plotting the median risk against the observed prevalence in each category. Points lying close to the diagonal line of identity (where predicted risk equals observed prevalence) indicate the accuracy of risk estimation.
Statistical analyses were performed using RStudio (RStudio Team (2019). RStudio: Integrated Development for R. RStudio, Inc., Boston, MA URL http://www.rstudio.com/). NT MoM values calculated at the time of screening with the Alpha software (Logical Medical Systems, London, UK) were used.
Results
Figure 1 shows the NT MoM probability plot. Deviation from a log-Gaussian distribution is apparent at an NT measurement of about 2.0 MoM rather than 2.5 MoM.

Probability plot of NT measurements in unaffected pregnancies from 2018 study. 8 The two horizontal lines show the positions of the NT upper truncation limits at 2.0 and 2.5 MoM.
Figure 2(a) and (b) shows validation plots for Down’s syndrome risk estimates calculated using the current NT upper truncation limits of 2.5 MoM and 2.0 MoM, respectively. Table 1 gives the numerical results shown in Figure 2(a) and (b). When the NT upper truncation limit is 2.5 MoM, the risk estimates are inaccurate at high risks (greater than about 1 in 10). In the highest risk category, over 50 times more affected pregnancies are predicted than observed: the predicted risk estimate and the observed prevalence, expressed as an odds (affected:unaffected) are 53.1:1 and 1:1.1, respectively.

Validation plots for Down’s syndrome risk estimates expressed as probabilities (1 in x) calculated using NT measurements from the 2018 audit, 8 with the current reduced unaffected NT standard deviation. 4 (a) Validation plot with NT upper truncation limit of 2.5 MoM. (b) Validation plot with NT upper truncation limit of 2.0 MoM. (The points plotted in the two highest risk categories are nearly superimposed.).
Numerical results for the validation plot in Figure 2.
NT: nuchal translucency; MoM: multiple of the median.
Reducing the NT upper truncation limit to 2.0 MoM brings the plotted points closer to the diagonal line of identity and thereby improves the accuracy of the risk estimates. With an upper truncation limit of 2.0 MoM in the highest risk category, the predicted risk estimate and the observed prevalence (both expressed as an odds) are 1:1.78 and 1:2.7, respectively.
Discussion
This study shows that the NT MoM upper truncation limit should be revised from 2.5 to 2.0 MoM as a result of the improved prevision of NT measurements over time. The less high upper truncation limit improves the accuracy of risk estimation in antenatal screening for Down’s syndrome. Retaining the 2.5 MoM upper truncation limit overestimates risk estimation for pregnancies with high NT MoM values. Although such pregnancies would probably be screen-positive, a truncation limit of 2.0 MoM avoids an excess of very high inaccurate risk estimates among women with screen-positive results.
The distribution of NT log10 MoMs is positively skewed, so that the distribution of NT measurements at higher MoM values (those above about 2.0 MoM) is not well estimated by a Gaussian distribution (applicable to about 0.4% of unaffected pregnancies). With a smaller standard deviation, the expected number of pregnancies with high NT MoMs is substantially less than that observed. Consequently, the likelihood ratio calculated from the overlapping Gaussian distributions of affected and unaffected pregnancies at high NT MoMs will be overestimated, and hence the risk of having an affected pregnancy will be overestimated. This is illustrated in the validation plot of Figure 2(a) where the NT MoM upper truncation limit is set at 2.5 MoM, which shows how the error is limited to women with the highest risk estimates.
Figure 3 shows a partial histogram of NT MoM values (between 1.5 and 3.0 MoM) in unaffected pregnancies. The figure also shows the proportions using a Gaussian distribution with and without truncation at 2.0 MoM. With an NT upper truncation limit of 2.0 MoM, the truncated NT distribution fits the observed data reasonably well, illustrating how it leads to improved accuracy of risk estimation.

Partial histogram of NT MoM values (between 1.5 and 3.0 MoM) in unaffected pregnancies from the 2018 audit. 8 The solid dotted line shows the Gaussian distribution of NT measurements. To show a single line, a weighted average for gestational age weeks 10 to 13 was used to calculate the NT MoM standard deviation. The horizontal line is specified by the truncation limit (2.0 MoM).
Revising the NT upper truncation limit from 2.5 MoM to 2.0 MoM will not reduce the detection rate because the effect is limited to pregnancies with very high risk estimates (greater than about 1 in 10) that would anyway be classified as screen positive. It, however, avoids the overestimation of risk among some pregnancies with the highest risk estimates and being limited in this way is robust to centre-to-centre variation in NT precision.
The improvement in the accuracy of risk estimation using a less high NT upper truncation limit of 2.0 MoM will apply to screening for trisomy 18 and trisomy 13 as well as for Down’s syndrome because the over estimation of risk for high NT MoM values arises from the persistence of right skewness in the distribution of log10 NT MoM values in unaffected pregnancies.
In conclusion, the NT MoM upper truncation limit should be revised from 2.5 to 2.0 MoM when used with the smaller NT standard deviation associated with the improved precision of current NT measurements.