This article deals with the state-of-the-art instrumentation and application in the field of solid state gas sensorics, ion mobility spectrometry and mass-spectrometry-related research for the detection and measurements of low gas and vapor concentrations. The advantages and disadvantages of gas-analytical devices and systems are discussed, as well as the possibilities of its complex and/or complementary applications. Ion mobility spectrometry–mass spectrometry and subsequent techniques based on solid-state gas sensors are proposed for planned medical study.
HardenCS. Ion mobility spectrometry for detection of chemical warfare agents 1960’s to the present. Int J Ion Mobil Spectrom2004; 7: 30.
2.
LiF. UV-ion mobility spectrometer coupled to mass spectrometer. Int J Ion Mobil Spectrom2001; 4: 100.
3.
BowersWDParsonsMLClementREet al.Trace impurities in solvents commonly used for gas-chromatographic analysis of environmental-samples. J Chromatogr2006; 2: 279.
4.
EicemanGAClementREKarasekFW. Analysis of fly-ash from municipal incinerators for trace organic-compounds. Anal Chem1979; 51: 2343.
5.
ZhangXKnochenmussRSiemsWFet al.Evaluation of hadamard transform atmospheric pressure ion mobility time-of-flight mass spectrometry for complex mixture analysis. Anal Chem2014; 86: 1661.
6.
PutonJKnapASiodlowskiB. Modelling of penetration of ions through a shutter grid in ion mobility spectrometers. Sens Actuat B2008; 135: 116.
7.
PohleRSimonESchneiderRet al.Fire detection with low power FET gas sensors. Sens Actuat B2007; 120: 669.
8.
KnoblauchJIllyaskuttyNKohlerH. Early detection of fires in electrical installations by thermally modulated SnO2/additive-multi sensor arrays. Sens Actuat B2015; 217: 36.
9.
Ritchie RK and Rudolph A. Environmental applications for ion mobility spectrometry. In: Proceedings of the 3rd international workshop on ion mobility spectrometry, 16–19 October 1994, Vol., 3301, p.193. Galveston, Texas: National Aeronautics and Space Administration.
10.
Brittain A, Bass P, Breach J, et al. Instrumentation for analyzing volatile organic compounds in inhabited enclosed environments. SAE Technical Paper Series 2000-01-2434, 2000.
11.
Budde KJ and Holzapfel WJ. Organic contamination analysis in semiconductor silicon technology. Detrimental “cleanliness” in cleanrooms”. In: Proceedings of the electrochemical society 98–1 on silicon material science and technology, 1 January 1998, p.1496. Munich, Germany: The Electrochemical Society.
12.
RasulevUKIskhakovaSSKhasanovUet al.Atmospheric pressure surface ionization indicator of narcotic. Int J Ion Mobility Spectrom2001; 4: 121.
13.
BuryakovIAKolomietsYN. Rapid determination of explosives and narcotics using a multicapillarycolumn gas chromatograph and an ion-mobility spectrometer. J Anal Chem2003; 58: 944.
14.
LigorTLigorMAmannAet al.The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS. J Breath Res2008; 2: 046006.
15.
JüngerMBödekerBBaumbachJI. Peak assignment in multi-capillary column – ion mobility spectrometry using comparative studies with gas chromatography-mass spectrometry for exhalred breath analysis. Anal Bioanal Chem2010; 396: 471.
16.
MiethMSchubertJKGrogerTet al.Automated needle trap heart-cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment. Anal Chem2010; 82: 2541.
17.
KushchISchwarzKSchwentnerLet al.Compounds enhanced in a mass spectrometric profile of smokers' exhaled breath versus non-smokers as determined in a pilot study using PTR-MS. J Breath Res2008; 2: 026002.
18.
LigorMLigorTBajtarevicAet al.Determination of volatile organic compounds in exhaled breath of patients with lung cancer using solid phase microextraction and gas chromatography mass spectrometry. Clin Chem Lab Med2009; 47: 550.
19.
BuszewskiBUlanowskaALigorTet al.Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry. Biomed Chromatogr2009; 23: 551.
20.
ChengZJWarwickGYatesDHet al.An electronic nose in the discrimination of breath from smokers and non-smokers: a model for toxin exposure. J Breath Res2009; 3: 036003.
21.
DragonieriSAnnemaJTSchotRet al.An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung Cancer2009; 64: 166.
22.
DragonieriSSchotRMertensBJAet al.An electronic nose in the discrimination of patients with asthma and controls. J Allergy Clin Immun2007; 120: 856.
BeauchampJKirschFBuettnerA. Real-time breath gas analysis for pharmacokinetics: monitoring exhaled breath by on-line proton-transfer-reaction mass spectrometry after ingestion of eucalyptol-containing capsules. J Breath Res2010; 4: 026006.
StorerMKDummerJDCookJet al.Increased concentrations of breath haloamines are not detectable in airways inflammation using SIFT-MS. J Breath Re2011; 5: 037105.
27.
HeraDLangfordVSMcEwanMJet al.Negative reagent ions for real time detection using SIFT-MS. Environments2017; 4: 16.
28.
PerlTBödeckerBJüngerMet al.Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry. Anal Bioanal Chem2010; 397: 2385.
29.
BaumbachJI. Process analysis using ion mobility spectrometry. Anal Bioanal Chem2006; 384: 1059.
30.
BaumbachJIWesthoffM. Ion mobility spectrometry to detect lung cancer and airway infections. Spect Eur2006; 18: 22.
31.
WesthoffMLitterstPFreitagLet al.Ion mobility spectrometry in the diagnosis of Sarcoidosis: results of a feasibility study. J Physiol Pharmacol2007; 58: 739.
32.
VautzWNolteJFobbeRet al.Breath analysis – performance and potential of ion mobility spectrometry. J Breath Res2009; 3: 036004.
33.
BasantaMKoimtzisTSinghDet al.An adaptive breath sampler for use with human subjects with an impaired respiratory function. Analyst2007; 132: 153.
34.
BasantaMKoimtzisTThomasCLP. Sampling and analysis of exhaled breath on human subjects with thermal desorption gas chromatography – differential mobility spectrometry. Int J Ion Mobility Spectrom2006; 9: 45.
35.
CovingtonJADer Schee VanMPEdgeASLet al.The application of FAIMS gas analysis in medical diagnostics. Analyst2015; 140: 6775.
36.
CovingtonJAWedlakeLAndreyevJet al.The detection of patients at risk of gastrointestinal toxicity during pelvic radiotherapy by electronic nose and FAIMS: a pilot study. Sensors2012; 12: 13002.
37.
AgapiouAAmannAMochalskiPet al.Trace detection of endogenous human volatile organic compounds for search, rescue and emergency applications. Trends Anal Chem2015; 66: 158.
38.
KingJKupferthalerAFrauscherBet al.Measurement of endogenous acetone and isoprene in exhaled breath during sleep. Physiol Meas2012; 33: 413–428.
39.
LeeJHHwangSMLeeDWet al.Determination of volatile organic compounds (VOCs) using Tedlar bag/solid-phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) in ambient and workplace air. B Korean Chem Soc2002; 23: 488.
40.
SchulzKJensenMLBalsleyBBet al.Tedlar bag sampling technique for vertical profiling of carbon dioxide through the atmospheric boundary layer with high precision and accuracy. Environ Sci Technol2004; 38: 3683.
41.
BeauchampJHerbigJGutmannRet al.On the use of Tedlar bags for breath-gas sampling and analysis. J Breath Res2008; 19: 046001.
42.
FilipiakWFilipiakAAgerCet al.Optimization of sampling parameters for collection and preconcentration of alveolar air by needle traps. J Breath Res2012; 6: 027107.
43.
BajtarevicAAgerCPienzMet al.Noninvasive detection of lung cancer by analysis of exhaled breath. BMC Cancer2009; 9: 348.
44.
SamotaevNNVasilievAAPodlepetskiBIet al.The mechanism of the formation of selective response of semiconductor gas sensor in mixture of CH4/H2/CO with air. Sens Actuat B2007; 7: 242.
45.
Vasiliev AA, Brida S, Ferrario L, et al. Development of silicon microheaters for chemoresistive gas sensors. In: Symposium on design, test, and microfabrication of MEMS and MOEMS, Paris, France, 30 March 1999, p.964.
46.
LaakiaJAdamovAJussilaMet al.Separation of different ion structures in atmospheric pressure photoionization – ion mobility spectrometry – mass spectrometry (APPI-IMS-MS). J Am Soc Mass Spect2010; 21: 1565.
47.
AdamovAViidanojaJKärpänojaEet al.Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer. Rev Sci Inst2007; 78: 044101.
48.
PedersenCSLauritsenFRSysoevAet al.Characterization of proton-bound acetate dimers in ion mobility spectrometry. J Am Soc Mass Spect2008; 19: 1361.
49.
MiekischWHengstenbergAKischkelSet al.Construction and evaluation of a versatile CO2 controlled breath collection device. IEEE Sen J2010; 10: 211.
50.
RuzsanyiVBaumbachJISielemannSet al.Detection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers. J Chromatogr A2005; 1084: 145.
51.
BaumbachJI. Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath. J Breath Res2009; 3: 1.
52.
MaddulaSBlankLSchmidAet al.Detection of volatile metabolites of Escherichia coli by multi capillary column coupled ion mobility spectrometry. Anal Bioanal Chem2009; 394: 791.
53.
EicemanGAKarpasZ. Ion mobility spectrometry, 2nd ed. Boca Raton, FL, USA: CRC Press, Taylor & Francis, 2005, pp. 337.
54.
FendR. Prospects for clinical application of electronic nose technology to early detection of Mycobacterium tuberculosis in culture and sputum. J Clin Microbiol2006; 44: 2039.
55.
XinZLeeSXuZet al.Recent progress on the development of chemosensors for gases. Chem Rev2015; 115: 7944.
56.
BarsanNKoziejDWeimarU. Metal oxide-based gas sensor research: how to?Sens Actuat B Chem2006; 121: 18.
57.
GotzAGraciaIPlazaJet al.A novel methodology for the manufacturability of robust CMOS semiconductor gas sensor arrays. Sens Actuat B Chem2001; 77: 395.
58.
NakhlehMKJeriesRGharraAet al.Detecting active pulmonary tuberculosis with a breath test using nanomaterials based sensors. Eur Resp J2014; 43: 1522.
59.
CapuanoRSantonicoMPennazzaGet al.The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs. Sci Rep2015; 5: 16491.
60.
PodlepetskyBI. Integrated hydrogen sensors based on MIS transistor sensitive elements: modeling of characteristics. Autom Remote Control2015; 75: 345.
61.
BykovaAAMalinovskayaLKKopylovPHet al.Exhaled breath analysis in diagnostics of heart failure with preserved ejection fraction. Eur J Heart Fail2016; 18: 146.
62.
Kopylov Ph. Y, Syrkin AL, Chomakhidze P.Sh, et al. Proton transfer reaction mass spectrometry of exhaled breath in diagnostics of heart failure. Kardiologiia 2016; 56: 37–41.
63.
SysoevAA. A mathematical model for kinetic study of analyte permeation from both liquid and gas phases through hollow fiber membranes into vacuum. Anal Chem2000; 72: 4221.
64.
AlexeyASysoevDMChernyshevSSet al.Development of an atmospheric pressure ion mobility spectrometer – mass spectrometer with an orthogonal acceleration electrostatic sector TOF mass analyzer. Anal Chem2013; 85: 9003.