Surgical gloves are worn to protect both the patient and the surgical team from transferred infections. Wearing two pairs of gloves, perforation indicator systems, glove liners, knitted gloves and triple gloving are said to offer additional protection. This paper presents the main findings from a Cochrane systematic review of 30 trials examining surgical gloving practice.
AarnioP., LaineT.2001Glove perforation rate in vascular surgeryVASA Journal for Vascular Diseases30(2) 122–124
2.
AveryC.M., GallacherP., BirnbaumW.1999a Double gloving and a glove perforation indication system during the dental treatment of HIV positive patients: are they really necessary?British Dental Journal186(1) 27–29
3.
AveryC.M.E., TaylorJ., JohnsonP.A.1999b Double gloving and a system for identifying glove perforations in maxillofacial trauma surgeryBritish Journal of Oral and Maxillofacial Surgery37(4) 316–319
4.
BerridgeD.C., StarkyG., JonesN.A.G., ChamberlainJ.1998A randomised controlled trial of double versus single gloving in vascular surgeryJournal of the Royal College of Surgeons of Edinburgh43(1) 9–10
5.
CalliotJ.L., CoteC., AbidiH., FabryJ.1999Electronic evaluation of the value of double glovingBritish Journal of Surgery86(11) 1387–1390
6.
DoyleP.M., AlviS., JohansonR.1992The effectiveness of double gloving in obstetrics and gynaecologyBritish Journal of Obstetrics and Gynaecology99(1) 83–84
7.
DuronJ.J., KeilaniK., ElianN.G.1996Efficacy of double gloving with a coloured inner pair for immediate detection of operative glove perforationsEuropean Journal of Surgery162(12) 941–944
8.
GaniJ.S., AnselineP.F., BissettR.L.1990Efficacy of double versus single gloving in protecting the operating teamAustralian and New Zealand Journal of Surgery60(3) 171–175
9.
HesterR.A., NelsonC.L., HarrisonS.1992Control of contamination of the operative team in total joint arthroplastyThe Journal of Arthroplasty7(3) 267–269
10.
JensenS.L., KristensenB., FabrinK.1997Double gloving as self protection in abdominal surgeryEuropean Journal of Surgery163(3) 163–167
11.
KovavisarachE., JaravechsonS.1998Comparison of perforation between single and double gloving in perineorrhaphy after vaginal deliveryAustralian and New Zealand Journal of Obstetrics and Gynaecology38(1) 58–60
12.
KovavisarachE., SeedadeeC.2002Randomised controlled trial of glove perforation in single and double gloving methods in gynaecologic surgeryAustralia and New Zealand Journal of Obstetrics and Gynaecology42(5) 519–521
13.
KovavisarachE., VanitchanonP.1999Perforation in single and double gloving methods for cesarean sectionInternational Journal of Gynecology and Obstetrics67(3) 157–161
14.
LaineT., AarnioP.2001How often does glove perforation occur in surgery?The American Journal of Surgery181(6) 564–566
15.
LaineT., AarnioP.2004a Glove perforation in orthopaedic and trauma surgeryJournal of Bone and Joint Surgery (Br)86(6) 898–900
16.
LaineT., KaipiaA., SantavirtaJ., AarnioP.2004b Glove perforations in open and laparoscopic abdominal surgeryScandinavian Journal of Surgery93(1) 73–76
17.
Marin BertolinM., Gonzales MartinezR., GimenezC.N., Marquina VialP., Amorroortu VeleyosJ.1997Does double gloving protect surgical staff from skin contamination during plastic surgery?Plastic and Reconstructive Surgery99(4) 956–960
18.
NaverL.P.S., GottrupF.2000Incidence of glove perforations in gastrointestinal surgery and the protective effect of double glovesEuropean Journal of Surgery166(4) 293–295
19.
NicolaiP., AldhamC.H., AllenP.W.1997Increased awareness of glove perforation in major joint replacementJournal of Bone and Joint Surgery (Br)79(3) 371–373
20.
PieperS.P., SchimmeleS.R., JohnsonJ.A., HarperJ.L.1995A prospective study of the efficacy of various gloving techniques in the application of erich arch barsJournal of Oral and Maxillfacial Surgery53(10) 1174–1176
21.
PunyatanasakchaiP., ChittacharoenA., AyudhyaN.I.N.2004Randomised controlled trial of glove perforation in single and double gloving in episiotomy repair after vaginal deliveryJournal of Obstetrics and Gynaecology Research30(5) 354–357
22.
RuddimanR., KarnadihardjaW., RuchiyatY., HanafiB.1999Efficacy of double versus single gloving in laparotomy proceduresAsian Journal of Surgery22(1) 85–88
23.
SackettD.L.1986Rules of evidence and clinical recommendations on use of antithrombotic agentsChest89(2 suppl) 2S–3S
24.
SandersR., FortinP., RossE., HelfetD.1990Outer gloves in orthopaedic proceduresJournal of Bone and Joint Surgery (Am)72(6) 914–917
25.
SeboldE.J., JordanL.R.1993Intraoperative glove perforationClinical Orthopaedics and Related Research297242–244
26.
St GermaineR.L., HansonJ., de GaraC.J.2003Double gloving and practice attitudes among surgeonsThe American Journal of Surgery185(2) 141–145
27.
SuttonP.M., GreeneT., HowellF.R.1998The protective effect of a cut-resistant glove linerJournal of Bone and Joint Surgery (BR)80(3) 411–413
28.
TannerJ., ParkinsonH.2006Double gloving to reduce surgical cross-infection (Cochrane Review)The Cochrane Library 2006 Issue 3, Chichester, John Wiley & Sons Ltd
29.
TannerJ., WraighteP., HowardP.2006Knitted outer gloves in primary hip and knee arthroplastyHip International16(1) 62–65
30.
ThomasS., AgarwalM., MehtaG.2001Intraoperative glove perforation - single versus double gloving in protection against skin contaminationPostgraduate Medical Journal77(909) 458–460
31.
TurnquestM.A., HowH.Y., AllenS.A., VossD.H., SpinnatoJ.A.1996Perforation rate using a single pair of orthopaedic gloves versus a double pair of gloves in obstetric casesThe Journal of Maternal-Fetal Medicine5(6) 362–365
32.
UnderwoodM.J., WeerasenaN., GrahamT.R., HosieK., DunningJ., BaileyJ.S., FirminR.K.1993Prevalence and prevention of glove perforation during cardiac operationsJournal of Thoracic and Cardiovascular Surgery106(2) 375–377
33.
WilsonS.J., SelluD., UyA., JafferM.A.1996Subjective effects of double gloves on surgical performanceAnnals of the Royal College of Surgeons of England78(1) 20–22